The UPS was on battery and the connected load exceeded the rated load of the UPS.The alarm is on with a constant tone and the UPS is off See Troubleshooting to order replacement batteries. Note: As a battery ages, the runtime capability decreases.

#Apc be600m1 full#

Leave the Back-UPS connected to AC power for ten hours while the battery charges to full capacity. The Back-UPS has an inadequate battery runtime Call a qualified electrician to correct the building wiring fault. The building wiring presents a shock hazard that must be corrected by a qualified electrical.ĭo not operate the Back-UPS. The Building Wiring Fault LED illuminates When utility power is restored the battery will recharge. At this point the user should save all open files, and shutdown the computer. The Back-UPS battery is near a total discharge state. The Back-UPS battery has approximately two minutes of remaining runtime. The POWER button flashes green in rapid succession. When AC power is restored the battery will recharge. The Back-UPS is operating normally on battery power. The Back-UPS is operating on battery power. The POWER button is green and flashes twice every 2 seconds It is not intended for use with motor driven equipment.Ĭontact APC Technical Support for more in depth troubleshooting. The output waveform is intended for computers and peripheral devices.

#Apc be600m1 software#

PowerChute software has performed a shutdown due to a power outage.Ĭonnected equipment does not accept the step-approximated sine waveform from the Back-UPS. The Back-UPS battery is completely discharged.Ĭonnect the Back-UPS to AC power and allow the battery to recharge for ten hours If the overload condition still occurs, replace the battery. Charge the battery for 24 hours to make sure it is fully charged. One at a time reconnect equipment to the Back-UPS. Remove all nonessential equipment connected to the outlets. Replacement batter is APCRBC154Ī Back-UPS overload condition has occurred. Refer to the section "Battery Replacement".Remove AC power and refer to the section "Connect the Battery" on page 1.The battery is near the end of useful life and should be replaced.The Back-UPS is on, the POWER button alternated green-red and the unit emits a constant tone Where applicable, check that the wall outlet is switched on. Make sure the power cord is securely connected to the wall outlet, and that there is AC power available from the wall outlet. The Back-UPS is not connected to AC power, there is no AC power available at the wall outlet, or the AC power is experiencing a brownout or over voltage condition. This document will assist you with basic troubleshooting steps.

apc be600m1

#Apc be600m1 install#

This may be due to a malfunction, configuration issue, or the install environment. What are the basic troubleshooting steps for the Back-UPS ES model BE600M1, BN650M1/BN650M1-CA/BN675M1?ĭuring normal operation, you may find your UPS not functioning as expected.